Cyberonics reneged on its "Lifetime Reimbursement Guarantee". Click on the image to learn how you can help...
Showing posts with label Responsive brain stimulation. Show all posts
Showing posts with label Responsive brain stimulation. Show all posts

Thursday, July 18, 2013

Real-time adaptive brain control: Combining a BCI with DBS to treat Parkinson’s

Real-time adaptive brain control: Combining a BCI with DBS to treat Parkinson’s

Adaptive DBS

Share This article

0
inShare

We have been following the advances in deep brain stimulation (DBS) pretty closely here at ET. Just the other week, we explained the motivations behind treatments for Parkinson’s disease with DBS electrodes placed in the subthalamic nucleus, and hinted at a couple of ways that they might be improved. Perhaps the biggest advance in DBS systems since they were first developed has just been reported by a group of researchers working in the Movement Disorders Group at Oxford University. By recording activity with what is essentially a brain-computer interface (BCI), the researchers were able to close the stimulation loop with direct feedback from the subthalamic nucleus. The ability to incorporate meaningful data from the implant user’s brain into the moment-to-moment control of the stimulation puts the one-size-fits-all DBS system on the fast track to obsolescence — and ushers in the new era of personalized implants.

Once activated, most DBS systems generate continuous pulses, typically at a frequency above 100Hz. Always-on stimulation fatigues not only the batteries, but more importantly the brain itself. The symptoms of Parkinson’s disease fluctuate continuously and any form of smart control needs to be fast to be effective. Previous research has demonstrated that the spike output of motor neurons in the cortex of a monkey could be used as feedback to provide better results than continuous stimulation. Directly implementing these results in humans calls for a bit more caution though — blunt exploratory implantation of multiple brain areas comes at a price. The Oxford group, led by Peter Brown, realized that the stimulation electrodes themselves can be used to record local field potentials. These signals are not the signatures of single cells, but can be thought of instead as more diffuse summary reports of larger groups of cells.

Monkey DBS

In order to use these averaged potentials for control, some criteria is needed to pass judgement on their desirability. Studies in Parkinson’s patients have consistently shown that subthalamic nucleus activity in the beta frequency band (3-30Hz) correlates with motor impairment. Brown’s group was able to build a control system that was able to filter and capture activity in this band, and then use it to control the stimulation current. The device was tested in eight patients and provided significant improvements over both continuous and random stimulation conditions.

This proof-of-principle demonstration provides a tantalizing glimpse of what lies ahead. For now, the control hardware is a bulky external system, although work on miniaturizing its footprint to fit inside the skull is ongoing. Once that happens, we have the essentials of two closely-related kinds of devices that are also under development in several labs. One is a device to police undesirable activity, like for example, seizures. In fact an important study in this area just appeared in the journal Neurosurgery. The other, more intriguing use is for what is commonly referred to as a “memory implant.”

DBS Electrode

DBS electrodes, reaching down into a human’s brain

There is really no substantial, convincing, evidence yet that memory implants are practical. The main problem is that we don’t know how to interpret what little brain activity we can manage to record. What I suspect we will find going forward is that, rather than attempting to build memory implants from scratch that access high-level areas of the brain (like the hippocampus), they will instead directly evolve from the on-board learning algorithms, and storage, that are built into motor control implants like those described here.

The pace of advance of these kinds of implants will be driven to a large degree by the pace at which they are made open. Interoperability between components is essential, as well as keeping the user in the loop to provide direct input to device designers. A huge boost in this area was just provided by Medtronic, the leading implant manufacturer, when it finally caved to overwhelming user demand for access to critical data generated by their implants. The irony of users having better feedback from an inexpensive Fitbit than from their $30,000 implant was not lost on vocal advocate, user, and TED Talk giver, Hugo Campos. Others were quick to jump on Medtronic CEO, Omar Ischrak when he tweeted how much he enjoyed access to his Runtastic data, yet at the same time denying feedback to users of his own products.

Opening implant data to users is harmless enough, although giving them unbridled control over critical parameters certainly has its risks. The larger community has already realized what the medical community has been slow to accept — the benefits of providing users with control over their implants far outweighs these risks, and that fact can no longer be ignored. Increasingly, we interact with our external environment through our personal electronic devices — that same power, and ease of interaction, for our inner space will be sought, demanded, and granted.

Now read: An ultrasonic intra-body communication network for bionic implants

Paper: DOI: 10.1002/ana.23951 – “Adaptive deep brain stimulation in advanced Parkinson disease” [Free PDF]

http://www.extremetech.com/extreme/161411-real-time-adaptive-brain-control-combining-a-bci-with-dbs-to-treat-parkinsons

Saturday, July 13, 2013

Responsive brain stimulation could improve Parkinson’s treatment

Responsive brain stimulation could improve Parkinson’s treatment

12 hours 53 minutes ago  -  July 12, 2013

Researchers in Oxford have demonstrated a significant improvement in the treatment of advanced Parkinson’s disease with deep brain stimulation.

Deep brain stimulation involves permanently inserting electrodes into the brain to deliver electrical impulses that cancel out the brain signals causing symptoms of Parkinson’s.

The new ‘adaptive’ system, successfully trialled by a Oxford University team based at the John Radcliffe Hospital, only delivers electrical stimulation when it detects the brainwaves responsible for causing the symptoms.

This is a significant refinement – present systems deliver continuous electrical stimulation to the brain.

The personalised system, which actively detects and responds to a patient’s brainwaves using a brain-computer interface, proved more effective than conventional stimulation. By using less than half the power of existing systems, it could also reduce the need for repeat operations to replace batteries.

Parkinson’s symptoms fluctuate on a moment by moment basis and the brain signal activity causing symptoms is not continuous.

Professor Peter Brown

Deep brain stimulation (DBS) is used to treat the difficulties in moving and involuntary shaking experienced by those living with advanced Parkinson’s disease, although it is not suitable for all patients.

Professor Peter Brown of the Nuffield Department of Surgical Sciences at the University of Oxford and consultant neurologist at Oxford’s John Radcliffe Hospital, led the study. He said: ‘Parkinson’s symptoms fluctuate on a moment by moment basis and the brain signal activity causing symptoms is not continuous, it comes in bursts. By only delivering stimulation when these bursts are detected, you increase the effectiveness and reduce the amount of electrical stimulation delivered to the brain, reducing power consumption.

‘DBS treatment is used by Parkinson sufferers for many years. We believe reducing the amount of electrical stimulation will lower the risk of side effects, although further research is needed on this aspect.’ Potential side effects of deep brain stimulation can include speech and cognitive deterioration.

His team’s proof of concept study is published in the journal Annals of Neurology. The research was supported by the National Institute for Health Research (NIHR) Oxford Biomedical Research Centre (a collaboration between Oxford University Hospitals NHS Trust and Oxford University), the Medical Research Council and The Wellcome Trust.

Professor Brown said a major advantage of adaptive DBS was the potential to significantly extend battery life.

He added: ‘At present patients need an operation every three or four years to replace the battery. These are elderly patients who are operated on under general anaesthetic. By extending battery life we can reduce the need for these operations.’

The adaptive system was trialled with eight patients. The trial was for 10 minute periods and compared to the effect of no stimulation, constant stimulation and randomised intermittent stimulation.

Professor Brown said: ‘We have believed for some time that this adaptive system could work, but this study has now proved the concept. Our conclusions were backed by independent assessment from experts at University College London.

‘However, this was a small-scale proof of concept study. We now need to trial the system for longer periods. For anything longer than a few hours we will need to overcome technological hurdles in terms of miniaturising the system.

‘The ultimate goal is a closed loop system small enough to be implanted in the body, similar to conventional DBS systems.’

http://www.healthcanal.com/brain-nerves/brain-diseases/40750-responsive-brain-stimulation-could-improve-parkinson%E2%80%99s-treatment.html